Search

Fixed gas detector

OC-F08 Fixed Odor Gas Detector

This online odor monitoring analyzer is also known as electronic‑nose system, designed for continuous real‑time quantification of malodorous gas concentration (OU value) and related pollutant components in industrial ambient air. Equipped with high‑precision sensor array and optimized anti‑interference algorithm, it simulates human olfactory perception to identify complex mixed odor pollution.

Fixed gas detector

Products Description

OC-F08 series online gas detector use the imported sensor and microcontroller technology, so with the advantages of high precision, good repeatability, stable signal, respond quickly, ect. Possible connected with many controller system, such as PLC, DCS, computer and other, with the function of remote monitor and alarm, data logger and analysis.

Common applications is gas safety inspection and alarm for industrial scene, such as petroleum refinery, chemical plants, LPG stations, boiler rooms, gas stations, paint spray booths, metallurgy, mining, fire, environmental protection, etc.

     64x64

Features

  1. 4‑20mA analog signal, RS485 digital signal and relay output available

  2. Independent air chamber design for simple calibration operation

  3. Infrared remote control, realize safe non‑contact operation

  4. Multiple certifications: CE, RoHS, CNEX, ATEX

  5. Diffusion sampling, pump‑suction sampling optional

  6. Supports customization for various industrial working conditions

  7. Die‑cast aluminum housing, IP66 protection grade

  8. Explosion‑proof design for hazardous explosive areas


Company Profile

We Henan Oceanus is located in Henan, a land with a long history and profound cultural heritage, has been dedicated to the research, development, production, and sales of Gas detection system and Environment equipment since its establishment. With exquisite technology and outstanding quality, we have won widespread recognition in the global marketing.

1

01

Business areas

As a leader in the field of Gas detector and Air quality monitor system, we Henan Oceanus will be continued to expand its business scope and provide customers around the world with customizable Air quality monitor system of various types and specifications.

02

Values and ideas

Our company upholds the core values of integrity and quality service, focusing more on friendship with our customers. We always adhere to integrity management, customer-centered, and provide a full range of pre-sales, sales, and after-sales services to ensure that customers can be worry-free when using our products.

03

Global Service Network

We have a comprehensive global service network, offering timely, professional pre-sales consultation, after-sales service, and technical support for overseas users. Regardless of where users are located, they can enjoy our attentive and thoughtful service.

04

Custom Service

With excellent products and services, Henan Oceanus Gas detector and Air quality monitor system have been exported to more than 100 countries around the world and have won widespread praise.


    product-800-500

 Parameter:

                    Applicable Gas

                    Odor gas

                    Detecting Range

                    0~10ppm, 0~100ppm

                    Resolution

                    0.01ppm

                    Sampling

                    Diffusion or pump-suction

                    Accuracy

                    ≤±3%F.S

                    Repeatability

                    ≤±1%

                    Zero drift

                    ≤±1%(F.S/year)

                    Sensor Type

                    Electrochemical

                    Sensor Life

                    2~3 years

                    Response Time (T90)

                    ≤20s

                    Alarming mode

                    Audible-visual alarm

                    Operating Environment

                    Temperature: -20℃~50℃

                    Humidity: ≤95%RH (non-condensing); if >90%RH, can add the filter

                    Pressure: 86kPa~106kPa

                    Working Voltage

                    24V DC (16~30VDC)

                    Output Signals

                    Three-wire system 4~20mA standard signals output; longest transmit distance is 1000m;

                    Four-wire system RS485 signal output; longest transmit distance is 1800m;

                    Two-level passive contact output:220VAC 3A, 24VDC 3A

                    Installation Means

                    Wall mounted, Pipe type (Thread:M40*1.5 )

                    Material of Body

                    Cast aluminum

                    Explosion-proof Index

                    Ex d IIC T6 Gb

                    Protection Grade

                    IP65

                    Electrical Interface

                    3/4″NPT(Female Screw),1/2″NPT(Female Screw)

                    Transmit Distance

                    ≤1800m

                    Dimension

                    200 mm×160 mm×80 mm(L×W×H)

                    Weight

                    About 1.5Kg


Our After-sales service:

1. OEM service for LOGO, model, Technical Parameters, Operation manual, etc.

2. Free calibration service and provide calibration methods.

3. One year warranty and lifetime warranty


How To Cooperate With Us?

We look forward to collaborating with more overseas gas detector and air quality monitor distributors and partners  to advance the development and application of gas detection and air quality monitoring technologies.

Our Address

No. 923, Floor 9, Unit 2, NO.78, Shangding Road, Zhengzhou, China.

Phone Number

+86 15981942832

E-Mail

info@china-oceanus.com

   

   

INQUIRY

CATEGORIES

CONTACT US

Contact:Oceanus Team

Mobile/WhatsApp:+86 15981942832

Mobile/WhatsApp:+86 13673683950

E-mail:info@china-oceanus.com

Add:No.923, Floor 9, Unit 2, NO.78, Shangding Road, Zhengzhou, China