What is the AQM-09?
AQM-09 gas detection system used to detect the pollutant gases.Particulate matter PM2.5 and PM10, TSP, Noise, Meteorological parameters . Combined with industrial imported sensor technology and unique heating dehumidification compensation device to make sure data accuracy.
What is the use of AQM-09?
It is designed to ensure the safety of the ambient air around you.
It can be used as the air quality camera around you.
Where can AQM-09 be used?
AQM-09 air quality monitoring system can monitor the dust in the urban environment, construction sites, tourist attractions, parks, quarries, open-pit mining, cement plants and road safety.
Our After-sales service:
1. OEM service for LOGO, model, Technical Parameters, Operation manual, etc.
2. Free calibration service and provide calibration methods.
3. One year warranty and lifetime warranty
Technical Parameter:
Items |
Description |
Specification |
Particle Modules |
Monitor method |
Continuously, automatically and real-time |
Working principle |
Light scattering technique |
|
Measurement data |
PM2.5, PM10,TSP |
|
Measuring range |
0~1000ug/m3 (Range can be extended) |
|
Response time |
≤60s |
|
Resolution |
1ug/m3 |
|
Parallelism |
<10% |
|
Sampling flow |
1.3L/min, ±0.15 |
|
Dehumidification |
With the automatic dehumidification function module |
|
Alarm function |
With high concentration alarm function, the platform can configure the alarm threshold |
|
Gas modules |
Monitor method |
Continuously, automatically and real-time |
Working principle |
High precision Electrochemical sensor |
|
Gas monitor |
SO2, NO2, CO, O3 |
|
T90 |
≤120s |
|
Sulfur Dioxide SO2 |
Measuring range: 0~500ppb Resolution: 1ppb Indication error: ±10%F.S Minimum detection value: 5ppb |
|
Nitrogen Dioxide NO2 |
Measuring range: 0~500ppb Resolution: 1ppb Indication error: ±10%F.S Minimum detection value: 5ppb |
|
Ozone O3 |
Measuring range: 0~10ppm Resolution: 0.1ppm Indication error: ±10%F.S Minimum detection value: 0.04ppm |
|
Carbon Monoxide CO |
Measuring range: 0~500ppb Resolution: 1ppb Indication error: ±10%F.S Minimum detection value: 5ppb |
|
Meteorological parameters |
Wind speed |
Range:0~45m/s Precision:±1m/s Output resolution:0.1m/s |
Wind direction |
Range:0~360° Precision:±3° Output resolution:1° |
|
Temperature |
Range:-30℃~50 ℃ Precision:±1℃ Output resolution:0.1℃ |
|
Humidity |
Range:0~95%RH Precision:±5%RH Output resolution:1%RH |
|
Air pressure |
Range:600~1100hPa Precision:±0.5hPa Output resolution:1hPa |
|
Noise monitor |
Measuring range: 30~130dB (A) |
|
Sampling frequency: <1s |
||
Dynamic analysis range: ≥100dB (A) |
||
Frequency weighting: A, C,Z |
||
Time weighting: F, S |
More information, pls contact:
Whatsapp: +8615981942832
Email: info@china-oceanus.com