Portable Oxygen Meter

2024-3-11      View:
  • Brand   Oceanus
  • Type   
  • Inquire Now
Introduction

 OC-905 Portable oxygen meter

Product Instruction:

OC-905 Portable Oxygen O2 gas detector with inner pump can accurately detect O2 gas concentration.The measuring range and gas type can be customized according to customer requirements.It can record 300000 groups data.With CE,ROHS,EPA,EX-PROOF,etc certification.

Applications:

The Portable Oxygen O2 gas detector with inner pump used in the gas safety inspection and alarm for industrial scene, such as chemical plants,laboratory,agricultural,LPG station,gas staion,etc.where need to inspect the O2 gas concentration.

Key Parameter:

Repeatability

≤±1%

Working principle

Electrochemical sensor 

Working environment

Temperature:-20℃~60℃

Humidity:10%-95%RH

Pressure:86Kpa~106Kpa

Measuring range

0~25%vol, 30%vol, 100%vol or Customized.

Resolution

0.01%vol

Display information

Gas type,Concentration value/unit,Time,Battery status,data storage status.

Data logger

300000 group of measuring data

Warranty

1 years

Protection grade

IP 66

Concentration unit

%LEL, %Vol, ppb, ppm, mg/m3

Quality standard GB15322.1-2003,GB3836.1-2010,GB3836.2-2010,GB3836.4-2010

Features:

Used the original imported sensor, semiconductor technology of ultra low power 32 bit microprocessor, 24 bit ADC acquisition 

chip, with the high accuracy.

It can accurately detect single gas concentration.

The measuring range and gas type can be customized according to customer requirements.

Pump-suction sampling.

High alarm and low alarm level.

Audible-visual alarm mode.


Technical Parameter:

Gas type

Combustible gas, Toxic gas, Carbon Dioxide, Oxygen, TVOC

Working principle

According to the gas

Measuring range

Customized

Resolution

Customized

Concentration unit

%LEL, %Vol, ppb, ppm,mg/m3

Precision

±≤3%F.S

Repeatability

≤±2%

Zero drift

≤±1%(F.S/year)

Sampling mode

Pump-suction sampling (Flow rate of 300ml/minute)

Data storage

Can record 100000 group of measuring data

Response time

T90≤30s (different gas sensors have different response times)

Recovery time

≤20s

Pre-heating time

≤60s

Display

LCD dot matrix display of the Gas type, gas concentration unit, gas concentration data, time, battery status, data storage status;

Working temperature

-20℃~50℃(Special requirements need to be customized)

Working humidity

10%-95%RH(non-condensing)

Working pressure

86Kpa~106Kpa

Explosion-Proof grade

Ex ib IIC T4 Gb

Protection grade

IP54

Alarm mode

Audible, visual. Two-color LED alarm light, sound≥75dB@25cm

Shell material

Aluminum alloy metal housing, ABS+PC

Power supply

3.7VDC, 2600mAh,Rechargeable lithium battery

DC5V USB charger

Charge time

≤6 hours

Working time

≥12 hours (Normal temperature electrochemical sensor)

Power consumption

0.5W

Dimensions

200.5*64.8*35.5mm (L*W*H)

Weight

0.46KG

Accessory

Box, instruction, USB charger , data line

Quality standard

GB15322.1-2003,GB3836.1-2010,GB3836.2-2010,GB3836.4-2010,GB12358-2006



More info, pls contact:


Whatsapp: +8615981942832

Add: No. 923, 9th Floor, Unit 2, No. 78, Shangding Road, Zhengzhou Area, Henan Pilot Free Trade Zone