Description:
OC-F08 series online gas detector used the original imported sensor and the ultra low power 32 bit microprocessor, so with the advantages of high precision, good repeatability, stable signal, respond quickly, etc. Possible connected with many controller system, such as PLC, DCS, computer and other, with the function of remote monitor and alarm, data logger and analysis.
Common applications is gas safety inspection and alarm for industrial scene, such as petroleum refinery, chemical plants, LPG stations, boiler rooms, gas stations, paint spray booths, metallurgy, mining, fire, environmental protection, etc., where need to inspect the Chlorine Dioxide (ClO2) gas concentration.
Technical Parameter:
Applicable Gas
Chlorine Dioxide (ClO2)
Detecting Range
0~1ppm、0~10ppm、0~50ppm、0~100ppm、0~200ppm or customized
Resolution
0.001ppm(0~1ppm);0.01ppm(0~100ppm);0.1ppm(0~200ppm)
Sampling
Diffusion or pump-suction, circulation selectable
Accuracy
≤±3%F.S
Repeatability
≤±1%
Zero drift
≤±1%(F.S/year)
Sensor Type
Electrochemical sensor
Sensor Life
2~3 years
Response Time (T90)
≤20s
Alarming mode
Audible-visual alarm(Optional)
Operating Environment
Temperature: -30℃~60℃ (Customized for special demands)
Humidity: ≤95%RH (non-condensing); if >90%RH, can add the filter
Pressure: 86kPa~106kPa
Working Voltage
24V DC(16~30VDC)
Output Signals
(Standard)Three-wire system 4~20mA standard signals output, available for PLC, DCS, etc;
(Optional) Four-wire system RS485 digital signal output;
(Optional) Frequency signal 200~1000Hz output;
Two-level relay output:220VAC 0.5A, 5VDC 0.5A
Installation Means
Wall mounted, Pipe type(Thread:M40*1.5 )
Material of Body
Cast aluminum
Explosion-proof Index
Ex d IIC T6
Protection Grade
IP66
Electrical Interface
3/4″NPT(Female Screw)、1/2″NPT(Female Screw)
Transmit Distance
≤2000m
Dimension
210 mm×140 mm×92 mm(L×W×H)
Weight
About 1.5Kg
Warranty
12 months
Standards
GB15322.1-2003,GB3836.1-2010,GB3836.2-2010,GB3836.4-2010