OC-1000 Portable CO Detector
Product Instruction:
OC-1000 Portable Gas Detector. It can detect up to 5 kinds of gases at the same time, and can also detect temperature and humidity, particulate matter and dust. Measuring range and gas type can be customized according to customer requirements. It has functions such as historical record log, real-time curve, target calibration, and alarm setting.
Features:
Built-in sensors measure gas concentrationTemp, Humidity.
Optional mini-printer.
Temp&Humidity testing range:Temperature: -40~120℃; Humidity: 0~100% RH
The measuring range and gas type can be customized according to customer requirements.
Multi-colored LED light bar indicates the level of leakage detected
Low battery indicator
Dimensions: 220*88*55mm
Weight:0.5KG
Particle filter, box, instruction, USB charger , data line, calibration cap.
Audible-visual-vibration alert.
With CE, ROHS,EPA certification.
Technical Parameter:
Gas type |
Combustible gas, Toxic gas, Oxygen, Carbon Dioxide, TVOC, etc. |
||
Working principle |
Catalytic combustion sensor for Combustible gas; Electrochemical sensor for Toxic gas and Oxygen gas; NDIR sensor for CO2, CH4, SF6; PID sensor for TVOC gas. |
||
Particle size |
Optional particle sensor of the channels: 0.5um, 1.0um, 2.5um, 10um |
||
Particle testing mode |
Quantity testing(PC/L) and Quality testing(ug/m3) |
||
Sampling mode |
Pump-suction sampling |
||
Measuring range |
According to different gas type |
||
Resolution |
According to different gas type |
||
Precision |
±3%F.S (or customized) |
||
Dust Temp & Humidity testing range |
Temperature: -40~120℃; Humidity: 0~100% RH |
||
Data storage function |
With the capacity of the 100000 group of measuring data, by the software could be transmitted to the computer. |
||
Printer |
Optional mini-printer. |
||
Response time |
≤20s(T90) |
Recovery time |
≤20s |
Repeatability |
≤±1% |
Linearity |
≤±1% |
Zero drift |
≤±1%(F.S/year) |
Concentration unit |
ppm, %vol, %lel, mg/m3 |
Display |
LCD display the Date, time, Temp& humidity, Gas concentration data, unit, status for the pump, alarm and battery. |
||
Operation language |
Chinese/English |
Alarm mode |
Audible, visual, vibration |
Gas Working temperature |
-30~60℃ |
Working humidity |
0-95%RH(non-condensing) |
Working pressure |
70Kpa ~ 200Kpa |
Explosion-proof grade |
Ex ia IIC T4 Ga |
Protection grade |
IP65 |
Shell material |
ABS+PC |
Dimensions |
220*88*55mm |
Weight |
0.5KG |
Standard accessory |
Particle filter, box, instruction, USB charger , data line, calibration cap. |
More infor, pls contact:
Whatsapp: +8615981942832
Add: No. 923, 9th Floor, Unit 2, No. 78, Shangding Road, Zhengzhou Area, Henan Pilot Free Trade Zone