Halogen gas leak detector OC-H902
Features:
◆ Detect all kinds of halogen refrigerants.
◆ Sensitivity adjusted at any time and it can be adjusted automatically to the best state of detecting.
◆ Inner precise IC with Ultra-Low consume circuit design, more stable, longer battery time.
◆ Tricolor visual display of battery voltage.
◆ Excellent sensor, high sensivity, longer use time.
Specifications and parameter:
◆ Operating temperature: 0℃ to 52℃ (30 to 125 )
◆ Maximum sensitivity: 6 gr/yr, for all halogenated refrigerants.
◆ Battery life: Approximately 50 hours normal use.
◆ Response time: Instantaneous.
◆ Work mode: Continuous, no limitation.
◆ Fixed Probe Length:20cm.
◆ Unit Dimensions:22.9cm x 6.5cm x 6.5cm.
◆ Warm-up time: Approximately 6 seconds.
◆ Reset Time: Two to ten second.
◆ Power Supply: 6V DC four cell 7# excellent batteries.
Applications:
◆ Detect leaks in other systems and storage/recovery containers. It will respond
to All halogenated (contains Chlorine of Fluorine) refrigerants. This includes,
but is not limited to:
CFCs e.g.R12,R11,R500,R503 etc...
HCFCs e.g.R22,R123,R124,R502 etc...
HFCs e.g.R134a,R404a,R125 etc...
Blends such as AZ-50. HP62. MP39 etc...
◆ Detect Ethylene Oxide gas leaks in hospital sterilizing equipment (it will detect the halogenated carrier gas).
◆ Detect SF-6 in high voltage circuit breakers.
◆ Detect most gases that contain chlorine, Fluorine and Bromine(halogen gases).
◆ Detect cleaning agents used in dry cleaning applications such as perchloroethylene.
◆ Detects halogen gases in fire-extinguishing system.
If you need halogen gas detector or other gas detector, welcome to contact with us.