Contact Us
Position:Home > News > Industry News

Gas Detector Installation Location And Usage Notes

2021-4-21      View:

I.The installation position


The installation position of oceanus detector, to achieve the best effect of detection is very important.Determine the position, need to consider the following factors: such as gas leak point and density, the density of detected gas and surrounding buildings, equipment condition, wind direction and perennial meteorological conditions, but also consider the location of windows and doors in the outdoor.


The following recommendations for user reference:


1: Instrument and measured gas could leak point to keep a proper distance.Too close to the reaction rate will be very fast, but if the leak is frequent, resulting in too much alarm, or long in the state of alarm people paralyzed; too far too slow reaction, and even no response.


2. Equipment to be installed under the leak point of the wind.


3.If the indoor installation, if the leak source in the outdoor, the equipment to be installed at the outlet.


4. To determine the height of the installation according to the proportion of the measured gas and air.


5. According to the measured gas may be the dew point of the situation, the frequency of personnel and stay time, select the number of instruments, in order to achieve the best economic results.


6. If equipment obsolete can be considered to increase the measured point.


7. Instrument to prevent the radiation of high temperature heat source, high temperature or low temperature will affect the use of the sensor effect and life.


OC-F08 gas detector with OC-8000 Gas detection controller system:

gas detection system

gas detection control system

It could connect the OC-F08 gas detector to make up as the industrial gas detection system. It will display the all gas concentration for each gas detector, when the gas concentration level up to the preset data, the controller will alarm with acoustic and light signal. Synchronously, the actuator will begin to drive the exhaust or the cut off valve and other equipment, in order to prevent the poisoning accident, explosion or fire. The OC-8000 Gas detection controller could guarantee the security of the industrial working place.


II.The use of matters needing attention


1 Please make sure that the measured gas is clean and free of dust.


2. When using the instrument, please ensure that the instrument is used within the specified range.


3. Do not use organic solvents, soap or silicon containing solution cleaning equipment, in order to avoid damage to the sensor.


4. Replace any components are likely to damage the structure of the intrinsic safety of the instrument, so before you go with the manufacturers to confirm the re operation.



If you have any other questions, please contact us in time.

contact oceanus