A new product------professional air quality abd environment test series
Introduction:
This series of products are monitor which can be real-time monitoring of carbon dioxide, formaldehyde, TVOC, temperature, humidity, particle pollution of PM2.5, PM10 and PM1.0 in the air. These measuring parameters are very important to guide us to know the quality of surrounding air. User can use these products to monitor the environment air and find some problems timely. These products are suitable for office, classroom, factory, hospital, Animal and plant breeding, environment monitoring, hotel, bathroom, kitchen, car and anywhere need to test.
Specification:
Sensor Type |
Semiconuctor |
Capacitive |
Infrared |
Measuring Parameter |
Temperature |
Humidity |
Carbon Dioxide |
Measuring Range |
-40~80℃ |
0~100%RH |
0~9999ppm |
Resolution |
0.1℃ |
0.1%RH |
1ppm |
Accuracy |
±0.5℃ |
±3%RH |
±50ppm±5% |
Response Time |
≤30s |
≤8s |
≤120s |
Sensor Type |
Laser |
Laser |
Laser |
Measuring Parameter |
Particle Pollution(PM2.5) |
Particle Pollution(PM10) |
Particle Pollution (PM1.0) |
Measuring Range |
0~999ug/m3 | 0~999ug/m3 |
|
Resolution |
1ug/m3 |
1ug/m3 |
1ug/m3 |
Accuracy |
±10% |
±10% |
±10% |
Response Time |
≤10s |
≤10s |
≤10s |
Attention:
1.Don't place the product in the environment which outrange temperature and humidity range.
2.Don't remove the internal device and the shell.
3.Please clean instrument by dry cloth.
4.Don't shake it strongly. Don't storage in a closed space for long time.
5.User should measure different places to calculate average as a result.
6.When measuring formaldehyde, please avoid alchol.