OC-905 Handheld Hydrogen H2 gas detector with high accuracy

2019-4-18      View:
  • Brand   Henan Oceanus
  • Type   OC-905
  • Inquire Now
Introduction

H2 gas alarm

Description:

OC-905 Portable H2 gas detector designed with the inner pump and the famous brand sensors, with stable performance and high accuracy. Used to detect the single gas concentration for the Combustible gas, Toxic gas, Carbon Dioxide, Oxygen, TVOC, etc. It can directly display the gas concentration data on the screen, the data also could be exported to the computer by USB cable.

For the portable Hydrogen gas detector, the common applications is gas safety inspection and alarm for industrial scene, such as petroleum refinery, chemical plants, LPG stations, boiler rooms, gas stations, paint spray booths, metallurgy, mining, fire, environmental protection, Poultry house, etc., where need to inspect the H2 gas concentration.

H2 gas detector

Features:
Used the original imported sensor, semiconductor technology of ultra low power 32 bit microprocessor, 24 bit ADC acquisition chip, so with the high accuracy.

2.5 inch dot matrix display interface.

All English operation menu and easy operation.

Unit data available for %vol, ppm and mg/m3.

The circuit installed the four layers of wire, so well anti-interference.

Explosion proof grade is Ex ib IIC T4 Gb.

H2 gas monitor

Function:

Inspect the gas concentration and alarm when it reaches preset alarm level.

High accuracy, good stability and good repeatability, long working life.

One-key operation to restore to factory default setting.

Adjustable two-stage audible-visual alarm threshold value.

Powered by rechargeable lithium battery with big capacity.

The built-in pump could be controlled.

H2 gas leakage monitor

Technical Parameter:

Gas type

Hydrogen (H2)

Measuring range

0~100ppm500ppm1000ppm5000ppm10000ppm40000ppm4%vol or Customized.

Working principle

Electrochemical sensor 

Resolution

0.1ppm, 1ppm or 0.01%vol

Precision

±≤3%FS or Customized

Repeatability

≤±1%

Zero drift

≤±1%(F.S/year)

Sampling mode

Pump-suction sampling (Flow rate of 300ml/minute)

Data storage

Can record 300000 group of measuring data

Response time

T90≤20s

Recovery time

≤20s

Pre-heating time

≤60s

Display

LCD dot matrix display of the Gas type, gas concentration unit, gas concentration data, time, battery status, data storage status;

Concentration unit

ppmmg/m3, %vol

Working environment

Working temperature: -2060

Working humidity: 10%-95%RH(non-condensing)

Working pressure: 86Kpa 106Kpa

Explosion-Proof grade

Ex ib IIC T4 Gb

Protection grade

IP66

Alarm mode

Audible, visual

Shell material

Metal

Power supply

3.7VDC, 2800mAh,Rechargeable lithium battery

DC5V USB charger

Charge time

≤6 hours

Working time

≥24 hours

Dimensions

135*65*35mm

Weight

0.5KG

Accessory

Box, instruction, USB charger , data line

Quality standard

GB15322.1-2003,GB3836.1-2010,GB3836.2-2010,GB3836.4-2010

H2 gas leakage alarm


H2 gas leak detector

More Products